The IoT-devices, LLC store is already on Etsy
November 06, 2023, Kyiv, Ukraine. Dear users, customers and partners! We are pleased to announce that with the launch of Etsy Payments service in Ukraine, we immediately opened our own…
November 06, 2023, Kyiv, Ukraine. Dear users, customers and partners! We are pleased to announce that with the launch of Etsy Payments service in Ukraine, we immediately opened our own…
Testing the emulator After we've built the emulator and programmed the ESP8266, we can test it to make sure it's working correctly. Having made the physical diagram and developed and…
Geiger counter emulator: what we need To build the Geiger counter module emulator, we'll need the following parts and materials: ESP8266 #1 as the main one (MCU_A, NodeMCU module);ESP8266 #2…
може сховати лістинг у акордеон? ####### ggreg20_esp8266_esphome.yaml ##### esphome: name: esphome_node1 # Controller Unique Name platform: ESP8266 # Platform type you have to select when creating new yaml-config in ESP Home board: nodemcuv2 # Controller type you have to select when creating new yaml-config in ESP Home wifi: ssid: "YourWiFiSSID" password: "SSIDPassword" # Enable fallback hotspot (captive portal) in case wifi connection fails ap: ssid: "Esphome Node1 Fallback Hotspot" password: "Cpxg9hRIBU7M" captive_portal: # Enable logging logger: # Enable Home Assistant API api: password: "APIpassword" ota: password: "OTApassword" # Just embedded test D3 (GPIO0) button on every ESP8266 Devboard # You can press D3 button several times to simulate incoming GGreg pulses binary_sensor: - platform: gpio name: "D3 Input Button" pin: number: 0 inverted: True mode: INPUT_PULLUP # Here we calc and include to the firmware a power and doze values of ionizing radiation as sensor outputs sensor: - platform: pulse_counter pin: D3 unit_of_measurement: 'mkSv/Hour' name: 'Ionizing Radiation Power' count_mode: rising_edge: DISABLE falling_edge: INCREMENT update_interval: 60s accuracy_decimals: 3 id: my_doze_meter filters: - sliding_window_moving_average: # 5-minutes moving average (MA5) here window_size: 5 send_every: 5 - multiply: 0.0054 # SBM20 tube conversion factor of pulses into mkSv/Hour - platform: integration name: "Total Ionizing Radiation Doze" unit_of_measurement: "mkSv" sensor: my_doze_meter # link entity id to the pulse_counter values above icon: "mdi:radioactive" accuracy_decimals: 5 time_unit: min # integrate values every next minute filters: - multiply: 0.00009 # obtained doze (from mkSv/hour into mkSv/minute) conversion factor: 0.0054 / 60 minutes = 0.00009; so pulses * 0.00009 = doze every next minute, mkSv. ####### END of ggreg20_esp8266_esphome.yaml #####