GGreg20_ES – souvenir Geiger counter
Copyright 2023 IoT-devices, LLC, Kyiv - Ukraine As participants in the DIY IoT market, we see that the same faulty or exhausted SBM-20 Geiger tubes are resold from hand to…
Copyright 2023 IoT-devices, LLC, Kyiv - Ukraine As participants in the DIY IoT market, we see that the same faulty or exhausted SBM-20 Geiger tubes are resold from hand to…
Problem and objective There are a lot of publications on the Internet on how to convert CPM (Counts per Minute) obtained from a Geiger tube to radiation levels. However, despite…
There are videos on the Internet showing that J305 tubes are very sensitive to UV rays. They literally go crazy under the influence of this type of radiation. We conducted…
We wondered what would happen if we took our DIY Geiger counter module GGreg20_V3 and put it in a freezer with a target temperature of -23 Celsius together with the…
Testing the emulator After we've built the emulator and programmed the ESP8266, we can test it to make sure it's working correctly. Having made the physical diagram and developed and…
може сховати лістинг у акордеон?
####### ggreg20_esp8266_esphome.yaml #####
esphome:
name: esphome_node1 # Controller Unique Name
platform: ESP8266 # Platform type you have to select when creating new yaml-config in ESP Home
board: nodemcuv2 # Controller type you have to select when creating new yaml-config in ESP Home
wifi:
ssid: "YourWiFiSSID"
password: "SSIDPassword"
# Enable fallback hotspot (captive portal) in case wifi connection fails
ap:
ssid: "Esphome Node1 Fallback Hotspot"
password: "Cpxg9hRIBU7M"
captive_portal:
# Enable logging
logger:
# Enable Home Assistant API
api:
password: "APIpassword"
ota:
password: "OTApassword"
# Just embedded test D3 (GPIO0) button on every ESP8266 Devboard
# You can press D3 button several times to simulate incoming GGreg pulses
binary_sensor:
- platform: gpio
name: "D3 Input Button"
pin:
number: 0
inverted: True
mode: INPUT_PULLUP
# Here we calc and include to the firmware a power and doze values of ionizing radiation as sensor outputs
sensor:
- platform: pulse_counter
pin: D3
unit_of_measurement: 'mkSv/Hour'
name: 'Ionizing Radiation Power'
count_mode:
rising_edge: DISABLE
falling_edge: INCREMENT
update_interval: 60s
accuracy_decimals: 3
id: my_doze_meter
filters:
- sliding_window_moving_average: # 5-minutes moving average (MA5) here
window_size: 5
send_every: 5
- multiply: 0.0054 # SBM20 tube conversion factor of pulses into mkSv/Hour
- platform: integration
name: "Total Ionizing Radiation Doze"
unit_of_measurement: "mkSv"
sensor: my_doze_meter # link entity id to the pulse_counter values above
icon: "mdi:radioactive"
accuracy_decimals: 5
time_unit: min # integrate values every next minute
filters:
- multiply: 0.00009 # obtained doze (from mkSv/hour into mkSv/minute) conversion factor: 0.0054 / 60 minutes = 0.00009; so pulses * 0.00009 = doze every next minute, mkSv.
####### END of ggreg20_esp8266_esphome.yaml #####